TradeZoro
Notifications

Manual

Error and warning codes

Every message the engine can give, in plain words.

Each message has a code, a line and column, and often a hint. Words in {braces} are filled in with your own names and numbers.

Lexer / header

Code Meaning
E101 Unexpected character {c}.
E102 Unterminated string (closing quote missing).
E103 Bad color literal {text} (use #RRGGBB or #RRGGBBAA).
E104 Bad number {text}.
E105 Indentation does not match any outer block.
E106 Source is too large (limit 256 KB).
E201 Missing header. Hint: put //@zscript 1 on the first line.
E202 Unsupported version {n}. Hint: use //@zscript 1.
E203 Unexpected {token}, expected {what}.
E204 Missing closing ) / ].
E205 Expected an indented block after {kw}.
E206 => default case must be last in switch.
E207 Nesting too deep (limit 128).
E208 break/continue outside a loop.
E209 = used in a condition. Hint: use == to compare, := to reassign.
E210 Reserved word {w} cannot be used here.

Checker

Code Meaning
E301 Missing indicator(...) declaration. Hint: add indicator("My script") after the header.
E302 indicator() declared twice.
E303 Unknown name {x}. Hint: Did you mean {y}?
E304 Unknown function {f}. Hint: Did you mean {g}?
E305 {x} is already declared in this scope. Hint: use := to change it.
E306 Cannot reassign {x} with := before it is declared. Hint: declare it with = first.
E307 {f} expects {n} arguments, got {m}.
E308 {f} has no parameter named {p}. Hint: Did you mean {q}?
E309 Argument {p} of {f} must be {type}, got {type2}.
E310 Cannot assign {type} to {x} declared as {type2}.
E311 {x} is {type}; cannot assign {type2}.
E312 Operator {op} cannot be used with {type} and {type2}.
E313 Condition must be bool or number, got {type}.
E314 Tuple has {n} values but {m} names.
E315 {x} is not a function.
E316 History [] needs a number of bars, got {type}.
E317 Built-in {x} cannot be reassigned.
E318 Function {f} calls itself (recursion is not allowed).
E319 Functions must be defined at top level.
E320 Method {m} does not exist for {type}. Hint: Did you mean {n}?
E321 Positional argument after a named one.
E322 Function {f} declared twice.
E330 Inputs must be called at top level with a literal default.
E340 {f} must be called at top level (not inside if/for/functions).
E341 Too many plots (limit 64).
E350 request.security expression uses the script variable {x}. Hint: compute it inside the expression, or move it into a function.
E351 lookahead is not allowed.
E352 Timeframe {tf} is lower than the chart timeframe.
E353 Too many request.security calls (limit 16).
W101 {f} is called only on some bars (inside if), so its state skips the other bars. Hint: compute it at top level and use the result inside the if.
W102 {f} inside a loop shares one state for every iteration.
W103 Variable {x} is never used.

Runtime

Code Meaning
E401 Script took longer than 20 s.
E402 History [{n}] is beyond max_bars_back ({m}). Hint: raise max_bars_back in indicator().
E403 Too many operations on one bar (limit 1,000,000). Hint: a loop may be too large.
E404 Loop ran more than 100,000 times on one bar.
E405 Array too large (limit 100,000 items) / too many items in all arrays (1,000,000).
E406 Map too large (limit 50,000 keys).
E407 String too long (limit 4,096).
E408 Too many {kind} drawings is not an error: oldest is removed. (Tables over 20 -> E408.)
E409 Division by zero is NOT an error: result is na.
E410 Index {i} out of range for array of size {n}.
E411 Called a method on na ({what}).
E412 {f} length must be a positive number, got {v}.
E413 Too many bars (limit 50,000).
E414 Function calls nested too deep (limit 64).
E415 request.security data for {sym} {tf} is not available (warning-level notice, value na).
E499 Internal engine error (report this script to support).

Education only. Not financial advice. Examples are teaching samples, not trading results.

Zscript is coming soon

The manual opens when Zscript launches.

Back to home